Purpose:
A guideline and pathway for the initial approach to ventilator management, blood gas monitoring, weaning, and extubation criteria for ELBW infants.
The guideline was developed with evidence-based principles, multi-disciplinary collaboration, and individualized and family-centered approaches to caring for the neonate.
Population:
premature infants 25-27 wks EGA
Purpose:
A guideline and pathway for the initial approach to ventilator management, blood gas monitoring, weaning, and extubation criteria for ELBW infants.
The guideline was developed with evidence-based principles, multi-disciplinary collaboration, and individualized and family-centered approaches to caring for the neonate.
Population:
premature infants 25-27 wks EGA
St. Luke’s Children’s Hospital, 190 E Bannock St. Boise, ID 83712
Scott A. Snyder, MD, snyders@slhs.org
Dedicated to providing a single-source home for resources on career planning, practice development, and clinical guidelines for neonatologists.
Copyright 2024 © Neonatology Solutions, LLC. All rights reserved.
Disclaimer: All content above is solely the work product of the authors. Neonatology Solutions, LLC, makes no endorsement or statement of safety, efficacy, or appropriateness of any of the protocols, pathways, guidelines, or algorithms contained within. They should be thoroughly reviewed against any available evidence prior to adoption. This content is for informational purposes only and should not be construed or relied upon as a standard of care. Any questions or concerns should be directed to the authors and/or the listed contact person. Good clinical judgement should always prevail when applying any standardized approach. We recommend that institutions review these protocols, pathways, guidelines, and algorithms and accept, modify, or reject them based on their own institutional resources and patient populations. Neonatology Solutions, LLC, assumes no liability for any outcomes arising from use of these tools.
Disclaimer: All content above is solely the work product of the authors. Neonatology Solutions, LLC, makes no endorsement or statement of safety, efficacy, or appropriateness of any of the protocols, pathways, guidelines, or algorithms contained within. They should be thoroughly reviewed against any available evidence prior to adoption. This content is for informational purposes only and should not be construed or relied upon as a standard of care. Any questions or concerns should be directed to the authors and/or the listed contact person. Good clinical judgement should always prevail when applying any standardized approach. We recommend that institutions review these protocols, pathways, guidelines, and algorithms and accept, modify, or reject them based on their own institutional resources and patient populations. Neonatology Solutions, LLC, assumes no liability for any outcomes arising from use of these tools.